Sound Silencer™ - Ceiling and Wall Panels
Rigid Porous ARPRO® Acoustical (P.E.P.P.) Ceiling and Wall Panels
Sound Silencer cleanable acoustical sound panels are unique – made from Rigid Porous ARPRO Acoustical (P.E.P.P.), these panels are Class A fire rated with STC and NRC values. Sound Silencer acoustical panels are great for gymnasiums, ice rinks, swimming pools, clean rooms, laboratories, food prep areas, firing ranges and anywhere else where noise control is important. The cleanable acoustical sound panels can be applied directly on wall and ceiling surfaces for attractive and effective sound control. Find out more here.
- High performance – both STC & NRC ratings
- Class A fire rated per ASTM E84
- No fiberglass – non-fibrous
- Water-resistant indoor
- Non-abrasive surface
- Indoor/outdoor usage
- Tackable surface
- Moisture-, impact-, bacteria- & fungi-resistant
- Lightweight & cleanable
- Low VOC Emissions – Passes CDPH V1.2 Test Standard and can contribute to LEED V4.1 EQ Credit: Low-Emitting Materials
-
Product Specs
Applications
Gymnasiums, Auditoriums, Classrooms, Swimming Pools, Ice Arenas, Clean Rooms, Food Processing Plants, Food Prep Areas, Cafeterias & Restaurants, Manufacturing Plants, Car Washes, Rooftop and Machine Enclosures, Gun Ranges, Dog Kennels, Locker Rooms.
Thickness
1"
2"Size
Standard Sizes
24" x 24"
24" x 48"
Custom Sizes
Up to 25" x 49"
Minimum quantities may apply. Inquire for details.Color
Charcoal, White
Installation Method
Adhesive, Direct Attach
Note to Installers
Sound Silencer™ is a thermal-molded acoustical sound panel. Although tough to see, one side of the sound suppressor panel will have injection and mold release marks these are circular marks that range in size and indent depth. These marks denote the back side of the cleanable acoustical sound panel so panels should be installed with these marks facing the wall or ceiling for best possible aesthetical outcome.
- Color Options
-
Acoustical Specs
Sound Silencer Ceiling and Wall Panel – NRC Results Panel Thickness/Density Testing Mount NRC Rating 1″ A 0.45 1″ A – 12″ spacing between panels 0.50 1″ D-20 – 3/4″ airspace 0.50 1″ C-25 – 1″ Echo Eliminator backer 0.80 2″ A 0.70 2″ A – 12″ spacing between panels 0.80 2″ D-20 – 3/4″ airspace 0.75 2″ C-25 – 1″ Echo Eliminator backer 0.90 Click here for expanded acoustical absorption data
Sound Silencer Ceiling and Wall Panel – Expanded Acoustical Absorption Data Thickness Testing Mount 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz NRC SAA 1″ A 0.05 0.06 0.21 0.80 0.65 0.75 0.45 0.44 1″ A – 12″ spacing between panels 0.04 0.07 0.20 0.83 0.81 1.00 0.50 0.49 1″ D-20 – 3/4″ airspace 0.06 0.13 0.51 0.79 0.62 0.79 0.50 0.52 1″ C-25 – 1″ Echo Eliminator backer 0.11 0.58 1.07 0.71 0.74 0.72 0.80 0.77 2″ A 0.07 0.21 0.81 0.85 0.93 0.88 0.70 0.68 2″ A – 12″ spacing between panels 0.09 0.21 0.82 1.11 1.11 1.12 0.80 0.80 2″ D-20 – 3/4″ airspace 0.10 0.29 0.99 0.74 0.90 0.93 0.75 0.72 2″ C-25 – 1″ Echo Eliminator backer 0.17 0.81 0.97 0.85 0.89 0.92 0.90 0.88 Sound Silencer Ceiling and Wall Panel – STC Results Panel Thickness/Density STC Rating OITC Rating 1″ 9 8 2″ 13 11 Click here for expanded transmission loss data
Sound Silencer Ceiling and Wall Panel – Expanded Transmission Loss Data Thickness 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz STC OITC 1″ 6 5 7 8 9 16 9 8 2″ 9 8 10 10 17 17 13 11 -
Material Performance
Fire Performance
Class A Fire Rated per ASTM E84
Light Reflectance
White - 90
Environmental
Passes CDPH Standard Method V1.2-2017 (VOC Emissions)
Passes ASTM C1338, G21, G22 test (No fungal growth)